The normal selection and capacity matching of frequency converter is actually very important!

2023-05-20 13:16:11

1、 Select frequency converter according to load characteristics


2、 When selecting frequency converter, the actual motor current value should be taken as the basis of frequency converter selection, and the rated power of motor can only be used as reference. Second, the frequency converter and high-order power factor will be considered.


3、 If the frequency converter needs long cable operation, the frequency converter should be enlarged by one gear, or the output reactor should be installed at the output end of the frequency converter.


4、 When the frequency converter is used to control several motors in parallel, it must be considered that the total length of the cables from the frequency converter to the motor is within the allowable range of the frequency converter.


5、 For some special applications, such as high ambient temperature, high switching frequency, high altitude and so on, the converter will reduce the capacity, so the converter should be enlarged by one gear


6、 When selecting the frequency converter for high-speed motor, it should be slightly larger than that of ordinary motor.


7、 When frequency converter is used in pole changing motor, the capacity of frequency converter should be selected to make its maximum rated current below the rated output current of frequency converter.


8、 When driving the explosion-proof motor, the frequency converter has no explosion-proof structure, so the frequency converter should be set outside the dangerous place.


9、 When the frequency converter is used to drive the gear reducer motor, the application range is restricted by the lubrication mode of the gear rotating part. Do not exceed the maximum allowable speed.


10、 When the frequency converter drives the wound rotor asynchronous motor, most of them use the existing motor. It is easy to cause over-current trip due to ripple current, so the frequency converter with larger capacity than usual should be selected..


11、 When the frequency converter drives the synchronous motor, the output capacity is reduced by 10% ~ 20% compared with the power frequency power supply.


12、 For the load with large torque fluctuation such as compressor, vibrator and oil pump with peak load, it is necessary to understand the power frequency operation and select the frequency converter with rated output current greater than its maximum current.


13、 When the frequency converter controls roots blower, due to its large starting current, we must pay attention to whether the capacity of the frequency converter is large enough.


14、 When selecting frequency converter, we must pay attention to whether its protection level matches with the situation on site.


15、 Single phase motor is not suitable for inverter drive.


If there is only a high reliability of the inverter itself, but the selection and capacity matching of the inverter are not appropriate, the frequency conversion speed control system composed of can not achieve high reliability, or even can not operate, then how to ensure the normal and efficient operation of the frequency conversion adjustment system?


We need to make sure that the capacity of the inverter matches. First of all, according to the nature of the load, select the type of inverter correctly. The general principle is what kind of load characteristics with what characteristics of the inverter.


(1) Constant torque production equipment -- in the speed range, the load torque is basically constant. Frequency converter with constant torque performance should be selected. Its overload capacity is 150% of rated current for 1 minute.


(2) Square torque production equipment -- in the speed range, the load torque is directly proportional to the square of the rotational speed, i.e. m ∝ N2, centrifugal fan and water pump are its typical representatives. The frequency converter with m ∝ N2 characteristic has smaller overload capacity, with 110% - 120% rated current overload for 1 minute,


(3) Constant power load production equipment - in the speed range, low speed and high torque; high speed and small torque, i.e. m? NC (constant). Typical equipment such as machine tools and winding mechanism.


Frequency converter manufacturer


label

QR code

The public,

Mobile station
The public, Mobile station

Contact

未標(biāo)題-8.png 0755-81719517
未標(biāo)題-10.png0755-81719530 未標(biāo)題-11.pngamb@ambition.com.cn
未標(biāo)題-12.pngFloor 1, 5 and 6, building 7, lijincheng science and technology industrial park, gongye dong road, longhua new district, shenzhen

Navigation

Home          About

Product      Case

Solution      Service

Job      News

Contact          

Copyright © Shenzhen Ambition Electronic Co., Ltd Record number:備案號(hào):粵ICP備12045920號(hào)
主站蜘蛛池模板: 麻豆成人久久精品二区三| 热久久久久久| 91果冻制片厂天美传媒| 久久e| 香蕉成人网| 国产麻豆免费| 日韩精品免费看| japanav在线| 欧美成人免费高清视频| 一个人看视频在线观看| 黄在线观看网站| 台湾xxx18| 国产精品动漫视频网站| 日本成年片高清在线观看| 91精品在线免费观看| 看片亚洲| 亚洲人成www在线播放| 国内精品一区二区三区| 四虎网址大全| 国产成人影院一区二区| 日本高清视频在线播放| 99国产热| 女老师9| 在线观看色视频| 久久99网站| 亚洲国产成人欧美激情| 国产一级精品毛片| 视频在线二区| 国产产一区二区三区久久毛片国语| 欧美影欧美影院免费观看视频| 69网站在线观看| 麻豆精品久久久| 亚洲一区欧美一区| 精品视频在线观看| 小叔用力插插深点| 国产香蕉视频在线| 色一欲一性一乱一区二区三区| 干干干操操操| 青青热久久综合网伊人| 99久久99视频| 欧美精品hd|