U/f constant control U/f control is to change the voltage of the motor power supply while changing the frequency of the motor power supply to keep the motor magnetic flux constant. In a wide range of speed regulation, the efficiency and power factor of the motor do not drop. Because it is the ratio of control voltage (Voltage) to frequency (Frequency), it is called U/f control. The main problem of constant U/f control is poor low-speed performance. When the speed is extremely low, the electromagnetic torque cannot overcome the large static friction force, and cannot properly adjust the torque compensation of the motor and adapt to the change of the load torque; the second is Can not accurately control the actual speed of the motor. Since the constant U/f inverter is speed open loop control, it can be seen from the mechanical characteristic diagram of the asynchronous motor that the set value is the stator frequency, which is the ideal no-load speed, and the actual speed of the motor is determined by the slip rate, so U/ The stability error existing in the constant control mode cannot be controlled, so the actual speed of the motor cannot be accurately controlled.


Slip frequency control The slip frequency is the difference frequency between the AC power frequency applied to the motor and the motor speed. According to the stable mathematical model of asynchronous motor, when the frequency is constant, the electromagnetic torque of the asynchronous motor is proportional to the slip rate, and the mechanical characteristic is a straight line.


Slip frequency control is to control torque and current by controlling the slip frequency. Slip frequency control needs to detect the speed of the motor to form a speed closed loop. The output of the speed regulator is the slip frequency, and then the sum of the motor speed and the slip frequency is used as the given frequency of the inverter. Compared with U/f control, its acceleration and deceleration characteristics and the ability to limit overcurrent are improved. In addition, it has a speed regulator, which uses speed feedback to form a closed-loop control, and the static error of the speed is small. However, to achieve steady-state control of the automatic control system, good dynamic performance cannot be achieved.


Vector control Vector control is also called field-oriented control. It was first proposed by F.Blasschke and others in West Germany in the early 1970s, and explained this principle by comparing DC motors and AC motors. This created a precedent for AC motors and equivalent DC motors. The method of vector control frequency conversion speed regulation is to change the stator AC currents Ia, Ib, Ic of the asynchronous motor in the three-phase coordinate system. Through the three-phase-two-phase transformation, it is equivalent to the alternating current Ia1 and Ib1 in the two-phase stationary coordinate system, and then through the rotation transformation according to the rotor magnetic field orientation, it is equivalent to the direct current Im1, It1 (Im1 is equivalent to the synchronous rotating coordinate system). It is the excitation current of the DC motor; It1 is equivalent to the armature current of the DC motor), and then imitate the control method of the DC motor to obtain the control value of the DC motor, and realize the control of the asynchronous motor through the corresponding coordinate inverse transformation. The emergence of vector control method makes asynchronous motor variable frequency speed regulation in an all-round superior position in the field of motor speed regulation. However, vector control technology requires correct estimation of motor parameters, and how to improve the accuracy of parameters is a topic of constant research.


Direct Torque Control In 1985, Professor DePenbrock from Ruhr University in Germany first proposed the theory of direct torque control. This technology largely solves the deficiencies of vector control. It does not indirectly control the rotation by controlling the current, flux, etc. But the torque is directly controlled as the controlled quantity. The advantage of torque control lies in the fact that torque control is to control the stator flux, essentially does not need speed information, the control is robust to all motor parameter changes except the stator resistance; the introduced stator flux observation The device can easily estimate the synchronous speed information, so it can easily realize the speed sensorless, this kind of control is called the speed sensorless direct torque control.


Frequency converter manufacturer


label

QR code

The public,

Mobile station
The public, Mobile station

Contact

未標(biāo)題-8.png 0755-81719517
未標(biāo)題-10.png0755-81719530 未標(biāo)題-11.pngamb@ambition.com.cn
未標(biāo)題-12.pngFloor 1, 5 and 6, building 7, lijincheng science and technology industrial park, gongye dong road, longhua new district, shenzhen

Navigation

Home          About

Product      Case

Solution      Service

Job      News

Contact          

Copyright © Shenzhen Ambition Electronic Co., Ltd Record number:備案號:粵ICP備12045920號
主站蜘蛛池模板: 久久国产精品免费一区二区三区 | 最新亚洲| 亚洲欧美精品久久 | 久久国产偷| 永久免费看黄在线播放 | 在线va| 天美麻豆国产传媒免费视频 | 欧日韩视频 | 操穴片| 午夜国产福利在线 | 欧美香蕉爽爽人人爽观看猫咪 | 羞羞视频破解版免费观看 | 亚洲综合极品香蕉久久网 | 亚洲熟区 | 亚洲视频在线一区二区三区 | 欧美网址在线观看 | 老司机亚洲精品影院在线观看 | 日韩一级黄色片 | 国产未成女年一区二区 | 亚洲欧美色视频 | 麻豆免费在线视频 | 日韩成人精品日本亚洲 | 国产1区2区在线观看 | 好男人好手机视频在线影视 | 久久va | 羞羞视频破解版免费观看 | 亚洲福利视频导航 | 免费99视频 | 窝窝影院午夜看片 | 狠狠入ady亚洲精品 狠狠热精品免费观看 | 清纯唯美亚洲综合五月天 | 亚洲激情在线观看 | 欧美日韩国产中文字幕 | 国产久视频 | 青丝影院高清版在线观看 | 99精品国产自在现线免费下载 | 久碰香蕉精品视频在线观看 | 日韩精品欧美精品中文精品 | 日日夜夜噜噜 | 青青青国产色视频在线观看 | 久热这里只有精品99国产6 |